1. AM to provide aluminium L-angle wih powder coated finished (colour to match window frame)
to close off gap between RC beam & wndow frame for all window at level 2F-7F at all 4 facades
at gridline E-M, 1D-8D, excluding corner window at terrace area.
2 WB to extend stone top piece at level 7F, gridline 3-6 / H-J to cover gap between RC beam and
steel frame.
3 SC to provide brickworks above RC beam as shown in section attached.